Air-cooled chiller features:
1) adopts imported compressor and satenoiseless, running, low noise, save electricity durability and long service life.
2) adopts imported high-precision PLC digital microcomputer temperature controllers, precise control of temperature control in the range of ± 0.1mm ° c, 3-45 degrees.
3) uses the condenser and evaporator, high heat efficiency, save electricity, more than 35%.
4) hasperfect safety protection system, anti-phase/owe phase, compressor over-current, overheating protection, high/low etc. Various protection, ensure safe operation of units.
5) within the machine with open stainless steel temperature-holder box, long service life, cleaning and maintenance convenient.
Performance parameters:
model | HY-0501A | HY-0502A | HY-0503A | HY-0505A | HY-1005A | HY-1006A | HY-1008A | HY-2010A | HY-2012A | HY-2015A |
large | BTU/H | 9145 | 21166 | 28541 | 38236 | 49503 | 58038 | 76513 | 99005 | 109990 | 131508 |
KW | 2.68 | 6.2 | 8.5 | 11.2 | 14.5 | 17 | 22.4 | 29 | 32.2 | 38.5 |
KCAL/H | 2305 | 5332 | 7310 | 9632 | 12470 | 14620 | 19264 | 24940 | 27692 | 33110 |
Compressor power(KW) | 0.85 | 1.65 | 2.44 | 3.24 | 4.25 | 4.9 | 6.5 | 8.5 | 9.5 | 12.2 |
Pump power(KW) | 0.25 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 |
Standard flowL/MIN | 20 | 30 | 35 | 35 | 50 | 65 | 80 | 95 | 95 | 150 |
Standard over caliber(DN) | 20 | 20 | 25 | 25 | 25 | 32 | 32 | 40 | 40 | 50 |
The power supply voltageAC | 1?220V/50HZ | 380~4150V/3PHASE/50HZ |
The condenser type | Efficient copper tube set series aluminium type + low noise axial flow fan |
Throttle device | capillary | Thermal expansion valve |
refrigerants | R22 |
evaporator | type | Water tank/shell and tube type/board change |
Tank capacityL | 20 | 35 | 55 | 55 | 78 | 140 | 140 | 215 | 215 | 365 |
Envelop dimensions | long(MM) | 570 | 900 | 1150 | 1150 | 1150 | 1300 | 1300 | 1300 | 1500 | 1800 |
wide(MM) | 420 | 500 | 560 | 560 | 560 | 720 | 720 | 770 | 770 | 1000 |
high(MM) | 715 | 1120 | 1060 | 1060 | 1060 | 1331 | 1331 | 1331 | 1331 | 1560 |
weight | (KG) | 45 | 86 | 150 | 175 | 185 | 340 | 350 | 450 | 475 | 700 |
Type, | HY- 3020A | HY- 3025A | HY- 5030A | HY- 5040A | HY- 7050A | HY- 7060A |
system | BTU/H | 192891 | 223344 | 262195 | 377247 | 455974 | 554775 |
cold | KW | 56.5 | 65.42 | 76.8 | 110.5 | 133.56 | 162.5 |
quantity | KCAL/H | 48590 | 56260 | 66048 | 95030 | 114862 | 139750 |
Compressor power (KW) | 16.2 | 21 | 24.2 | 32.34 | 39.84 | 47.9 |
Pump power (KW) | 1.5 | 2.2 | 3.75 | 3.75 | 5.6 | 5.6 |
Standard flowL/MIN | 180 | 220 | 250 | 300 | 385 | 450 |
Standard over caliber (DN) | 50 | 65 | 65 | 80 | 80 | 100 |
The power supply voltageAC | 380~4150V/3PHASE/50HZ |
The condenser type | Efficient copper tube set series aluminium type + low noise axial flow fan |
Throttle device | Thermal expansion valve |
refrigerants | R22 |
evaporator | type | Water tank/shell and tube type/board change |
Tank capacityL | 500 | 520 | 530 | 620 | 750 | 920 |
size | long (MM) | 2050 | 2200 | 2330 | 2500 | 2550 | 2950 |
wide (MM) | 1000 | 1000 | 1000 | 1200 | 1200 | 1350 |
high (MM) | 1725 | 1720 | 1720 | 2100 | 2150 | 2200 |
| (KG) | 860 | 1200 | 1480 | 1550 | 1680 | 1780 |
Air-cooled chiller's note:
The refrigeration freezing water outlet temperature conditions: 7 degrees Celsius, frozen water inlet temperature 12 degrees Celsius, chilled water inlet and outlet water temperature, temperature environment for 5 degrees 35 degrees Celsius, the condenser and evaporator dirt coefficient for 0.0001 m ² kcal/h c,